The Honeywell 05701-A-0283 functions as the primary Control Card and Sensor Drive Module for the System 57 gas detection platform. This module provides the essential interface between field-mounted gas sensors and the central control rack. It supports both catalytic bead sensors (mV signal) and 4–20 mA transmitters, converting raw analog inputs into precise digital data for alarm evaluation. Engineered for mission-critical industrial safety, the 05701-A-0283 ensures continuous monitoring of hazardous, toxic, or combustible gases in environments like offshore platforms, chemical refineries, and pharmaceutical cleanrooms. It powers the sensor head while simultaneously processing signal fluctuations to trigger rapid safety responses.
| Category | Specification Details |
|---|---|
| Model Number | 05701-A-0283 |
| System Series | Honeywell System 57 |
| Input Signal Types | Catalytic (mV) or 4–20 mA Transmitter |
| Input Channels | Single-channel analog input |
| A/D Resolution | 12-bit conversion |
| Power Supply | 24 VDC (Backplane Powered) |
| Power Consumption | 5 W |
| Communication | Modbus RTU, RS-485 |
| Isolation | Galvanic isolation (Input to System) |
| Accuracy | ±0.5% FS (Full Scale) |
| Operating Temp | –20°C to +50°C (–4°F to +122°F) |
| Dimensions | 170 × 25 × 112 mm |
| Weight | 0.165 kg (Net) / 0.02 kg (Module Core) |
Dual-Signal Versatility: The 05701-A-0283 accepts both low-level millivolt signals from catalytic sensors and standard 4–20 mA current loops. This versatility allows facilities to standardize on a single control card type while deploying different sensor technologies for various gas hazards.
Proactive Diagnostic Monitoring: The module incorporates continuous self-diagnostics to identify sensor wiring faults, open circuits, or short circuits. By detecting these issues instantly, the system prevents "fail-to-safe" blindness and reduces maintenance downtime in critical monitoring zones.
Superior Signal Integrity: Integrated galvanic isolation shields the System 57 backplane from field-generated electrical noise and ground loops. This protection ensures that high-frequency interference from nearby motors or drives does not cause false alarms or erratic gas readings.
High-Density Rack Integration: The slim 3U rack-mount design allows for the installation of multiple control cards in a single enclosure. This high-density architecture minimizes cabinet space requirements while providing independent, localized control for every gas detection point.
Does this card provide power to the gas sensor?Yes. The 05701-A-0283 acts as a sensor drive module, providing the regulated operating voltage required for catalytic bead sensors and 4–20 mA transmitters via the field wiring.
Can I use this module with third-party gas transmitters?The module is fully compatible with any standard 4–20 mA 2-wire or 3-wire gas transmitter, regardless of the manufacturer, provided the signal falls within the 12-bit resolution range.
Is this product "Brand New"?We guarantee that this 05701-A-0283 is 100% Brand New and Original Honeywell equipment. We ship the units in their original factory packing with a 12-month warranty.
How far can the sensor be located from this control card?Using high-quality shielded twisted-pair cabling, you can locate the sensor up to 1000 meters away from the 05701-A-0283 module while maintaining signal accuracy.